Influence of Chained Masonry on the Seismic Response of Reinforced Concrete Buildings

Authors

  • Abdelkader NOUR Laboratory Materials and Processes of Construction, Faculty of Science and Technology, University of Abdelhamid Ibn Badis, Route natoinale N 11, kharouba, 27000 Mostaganem, Algeria https://orcid.org/0000-0002-3077-6681
  • Abdelkader BENANANE Laboratory Materials and Processes of Construction, Faculty of Science and Technology, University of Abdelhamid Ibn Badis, Route natoinale N 11, kharouba, 27000 Mostaganem, Algeria https://orcid.org/0000-0002-5527-1268
  • Humberto VARUM CONSTRUCT-LESE, Department of Civil Engineering, Faculty of Engineering, University of Porto, Porto 4200-465, Portugal https://orcid.org/0000-0003-0215-8701

DOI:

https://doi.org/10.48048/wjst.2021.13194

Keywords:

Chained masonry wall, Seismic response, Reinforced concrete building, Period, ETABS

Abstract

The influence of chained masonry walls, which represents a special case of masonry infill without gap, on the seismic response of reinforced concrete buildings is extremely important due to their wide use in this type of building. We can consider the period of building as the key parameter to study this influence. In this article, we had carried out a comparative study of several 2D models of a multi-storey reinforced concrete building with a brick chained masonry wall using the response spectrum method in the ETABS finite element software, following the prescriptions of the current Algerian seismic code. This study included the use of the number of spans, the span length, the number of storeys, the thickness of the chained masonry wall, the ground soft storey, the openings in the walls, and the short column for studying the influence of these to the walls. The values from the numerical simulation were compared with those from the formula of the period of building, provided by both the Algerian and European codes. Based on the results obtained, we were able to assess the influence of chained masonry walls on the seismic response on this type of buildings. Through this article, we have concluded that these walls have a great influence on the overall behavior of reinforced concrete buildings under seismic loading.

HIGHLIGHTS

  • Clarify the importance of numerical simulation of chained masonry walls in the design of reinforced concrete buildings
  • Give recommendations to the current Algerian seismic code for properly design the infilled buildings with chained masonry
  • Know the great danger marked in the current conceptions, which neglect these walls in the phase of conception
  • Give to the infilled reinforced concrete buildings an adequate design in case of earthquake loadings

GRAPHICAL ABSTRACT

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

M Ferraioli and A Lavino. Irregularity effects of masonry infills on nonlinear seismic behaviour of RC buildings. Math. Probl. Eng. 2020; 2020, 4086320.

MM Abdelaziz, MS Gomma and H El-Ghazaly. Seismic evaluation of reinforced concrete structures infilled with masonry infill walls. Asian J. Civ. Eng. 2019; 20, 961-81.

L Cavaleri, PG Asteris, CC Repapis and EV Repapi. Fundamental period of infilled reinforced concrete frame structures. 2017; 13, 929-41.

MM Abdelaziz, M Gomaa and H El-ghazaly. Effect of unreinforced masonry infill walls on seismic performance. Open Civ. Eng. J. 2017; 11, 919-31.

ME Ahmad, N Ahmad, S Pervez, A Iqbal, AZ Khan, ME Rahim, W Hassan, K Umer and K Khan. Seismic performance evaluation of modern bare and masonry-infilled RC SMRF structures. 2019; 2019, 6572465.

P Christou and C Venizelou. The contribution of the infill walls to the lateral strength of concrete frames. Open. Construct. Build. Tech. J. 2019; 13, 114-22.

FEMA 306. Evaluation of earthquake damaged concrete and masonry wall buildings: Basic procedures manual. FEMA, Washington DC, 1998.

F Christiana, N Kyriakides, CZ Chrysostomou and E Georgiou. Finite element model of masonry-infilled RC frame. In: Proceedings of the 16th European Conference on Earthquake Engineering, Thessaloniki, Greece. 2018.

AR Amalia and D Iranata. Comparative study on diagonal equivalent methods of masonry infill panel. 2017; 1855, 030011.

A Banik and L Halder. Period formula for reinforced concrete buildings with infill walls. 2016; 857, 177-82.

PG Asteris, CC Repapis, F Foskolos, A Fotos, AK Tsaris. Fundamental period of infilled RC frame structures with vertical irregularity. Struct. Eng. Mech. 2017; 61, 663-74.

S Shan, S Li, MM Kose, H Sezen and S Wang. Effect of partial infill walls on collapse behavior of reinforced concrete frames. Eng. Struct. 2019; 197, 109377.

RD E Design, ET DE Calculation, and DE S Masonry, C 2.45 rules for the design and calculation of masonry.

C National and DER Appliquee. Rules parasismiques algeriennes RPA 99 / version 2003. 2003.

CSI Analysis Reference Manual, Avaliable at: https://wiki.csiamerica.com/display/doc/CSI+ Analysis+Reference+Manual, accessed May 2020.

NF En. Eurocode 8, norme européenne. 2005.

Seismosoft. SeismoStruct 2018 user manual. 2018.

Downloads

Published

2021-08-13

How to Cite

NOUR, A. ., BENANANE, A. ., & VARUM, H. . (2021). Influence of Chained Masonry on the Seismic Response of Reinforced Concrete Buildings. Walailak Journal of Science and Technology (WJST), 18(16), Article 13194 (12 pages). https://doi.org/10.48048/wjst.2021.13194